Minimum night flow (MNF) analysis, step by step
A worked minimum night flow analysis: find the night minimum, subtract legitimate use, apply the night-day factor and check the result against the balance.
Industry · 12 October 2026
The IWA water balance separates billed consumption, unbilled use and water losses. Real losses are calculated from the remaining volume, so errors in the input data can change the leakage estimate.

Updated 3 November 2026: added a free Excel worksheet and a worked example.
Utilities have not always used the same definitions for water losses. For example, firefighting and meter errors could be included in different categories, making comparisons difficult.
The International Water Association (IWA) and American Water Works Association (AWWA) established a common framework. It separates authorised use from apparent and real losses, so utilities can account for water consistently.
The balance also provides the annual real-loss volume used in the Infrastructure Leakage Index (ILI). ILI compares this with estimated unavoidable annual real losses, which requires network and pressure data. The EU Drinking Water Directive allows ILI or another appropriate method for assessing leakage.
The key point: a balance that adds up is not proof that its inputs are correct. In a top-down water balance, real losses are calculated as the remainder.
| System input volume | Authorised consumption | Billed authorised consumption | Billed metered consumption (incl. water exported) | Revenue water |
| Billed unmetered consumption | ||||
| Unbilled authorised consumption | Unbilled metered consumption | Non-revenue water | ||
| Unbilled unmetered consumption | ||||
| Water losses | Apparent losses | Unauthorised consumption | ||
| Customer metering inaccuracies and data-handling errors | ||||
| Real losses | Leakage on transmission and distribution mains | |||
| Leakage and overflows at storage tanks | ||||
| Leakage on service connections up to the point of customer metering |
The two main calculations are:
Water losses = System input volume − Authorised consumption
Real losses = Water losses − Apparent losses
NRW includes leakage, but also authorised unbilled use and losses caused by metering or data errors. It should not be reported as leakage alone.
Download the water balance worksheet (.xlsx, English)
The workbook includes blank fields for your own volumes, an illustrative example beside them, and formulas for authorised consumption, apparent losses, real losses and non-revenue water. Record each input’s source, assumptions and uncertainty in the amber fields. Unknown volumes should remain blank; enter zero only when you can support it.
Before filling it in, collect:
This is a starter worksheet for understanding and reviewing the balance. It does not calculate ILI, assign a data-validity grade or establish confidence bounds. For the complete AWWA audit workflow, see the AWWA Free Water Audit Software.
These figures are invented for an annual example. They are not customer data or a benchmark. All volumes cover the same network and year.
| Input | Annual volume |
|---|---|
| System input volume | 1,000,000 m³ |
| Billed metered consumption, including any billed metered exports | 690,000 m³ |
| Billed unmetered consumption | 10,000 m³ |
| Unbilled metered consumption | 5,000 m³ |
| Unbilled unmetered consumption | 15,000 m³ |
| Unauthorised consumption | 5,000 m³ |
| Customer metering inaccuracies | 25,000 m³ |
| Data-handling errors | 10,000 m³ |
The calculation is:
The 300,000 m³ of NRW therefore includes 20,000 m³ of authorised unbilled use, 40,000 m³ of apparent losses and 240,000 m³ of real losses. Calling the whole 30% “leakage” would overstate the calculated real-loss volume by 60,000 m³. The percentage describes this example; it is not a target for comparing different utilities.
Suppose a bulk-meter review increases the example’s input volume by 20,000 m³, from 1,000,000 to 1,020,000 m³. Keep every other input unchanged. Calculated real losses rise from 240,000 to 260,000 m³, an 8.3% increase in the estimate.
That adjustment changes our estimate. It does not demonstrate that a new leak developed. The balance still adds up in both cases, which is why source checks and independent leakage estimates matter.
System input volume is all water entering the defined system during the reporting period, including water from the utility’s own production and imports. For a distribution-system balance, use water entering the network after treatment, not raw water abstracted upstream.
Define the boundary first and account for every inlet. In the table above, billed metered exports are included in authorised consumption. Do not also subtract them from input. If you use a balance that excludes exports, adjust the boundary and calculations consistently.
Check bulk-meter accuracy and use the same period for all volumes. With other inputs unchanged, a 2% error in system input changes calculated real losses by 2% of the input volume.
Authorised consumption is water used with the utility’s permission. It has four components:
Document these estimates. Leaving unbilled use at zero without evidence can overstate real losses.
Apparent losses are unauthorised use and consumption missed or incorrectly recorded by customer meters and data systems. The table groups them into two components:
Apparent losses can reduce billing revenue. They are generally valued using the applicable customer tariff, while real losses are generally valued using the cost of producing or purchasing water. Recoverable revenue depends on tariffs and whether the consumption can be billed.
Mechanical meters can under-register as they wear, particularly at low flow. Age alone does not establish the error: test a representative sample of the meter fleet.
Real losses are water physically lost from the system:
This is an accounting boundary. It does not, by itself, determine who owns the pipe or must repair it.
In a top-down balance, real losses are calculated by subtraction:
Real losses = System input volume − Authorised consumption − Apparent losses
With all other inputs unchanged, the effect on the calculated result is:
Errors in input volume, authorised consumption or apparent losses affect the calculated remainder. They can increase or decrease the estimate, and some may cancel out. A total that adds up does not detect these errors; negative losses or implausible trends can still flag a problem.
Check the data quality and compare the result with an independent leakage estimate before using it to plan work.
Minimum night flow is one useful check in a metered zone. Demand is often lowest around 02:00–04:00, but the timing and level depend on local users.
Start with net zone inflow, accounting for outlets and changes in storage. Subtract customer night use, including households, industry and tank filling. Closed-loop circulation inside a building does not itself consume supply water. The remainder estimates leakage at night, not annual leakage volume.
To compare it with the water balance, convert it to a volume for the same area and period, allowing for pressure changes and changes in leakage over time. A large difference calls for checking both methods: meters, boundaries, night-use assumptions and pressure adjustments.
Record the source and uncertainty of each volume. Measured values also need checks:
| Cell | Typically |
|---|---|
| System input volume | Measured; verify bulk-meter accuracy |
| Billed metered consumption | Measured; test for under-registration |
| Billed unmetered consumption | Estimated; document the basis |
| Unbilled metered consumption | Measured; collect all relevant records |
| Unbilled unmetered consumption | Estimated; document activities and volumes |
| Unauthorised consumption | Estimated; record assumptions and evidence |
| Meter inaccuracies and data-handling errors | Estimated from meter tests and data checks |
| Real losses | Calculated remainder; affected by uncertainty in the inputs |
Weak estimates can leave substantial uncertainty in real losses. Report that uncertainty and prioritise improvements by their likely effect on the result, not just by the size of a component.
Start with a clear system boundary and a common reporting period. Verify bulk meters, record unbilled use and test customer meters. Where practical, divide the network into metered zones so you can investigate differences locally.
Divako water loss management brings input readings, consumption data and network zones together. It helps validate readings, align periods and update calculations as data arrives. Estimates still need evidence and review.

A worked minimum night flow analysis: find the night minimum, subtract legitimate use, apply the night-day factor and check the result against the balance.

What VEE means for meter data: the validation checks that matter, when estimation is allowed, how edits must be recorded, and what the EU rules and IEC 61968-9 expect.

A worked ILI calculation: build the water balance, find the four UARL inputs and check the result with a practical network example.